Double velour vascular prosthesis

 

Product Characteristics

DALLON® double velour vascular prostheses are knitted of polyester yarn.

DALLON® prostheses are characterized by:

 

·      optimum flexibility,

·      diameter retention,

·      easy anastomosis with surgical sutures,

·      no fraying on cut ends (including different cut endings),

·      low mass,

·      medium porosity of the walls, which need preclotting,

·      high mechanical strength,

·      color marking line.

Product Range

TRICOMED S.A.  manufactures two kinds of DALLON® double velour grafts:

 

DALLON® STRAIGHTS

 

SWW Symbol

Internal diameter

(mm)

 

Standard length

(mm)

 

Elongation

(mm)

1346-410

4

300

500

6

300

500

8

300

500

10

300

500

12

300

500

14

300

500

16

300

500

18

300

500

20

300

450

22

300

450

24

300

450

 

DALLON® BIFURCATIONS

 

 

SWW

Symbol

Internal diameter

(mm)

Standard length

( mm )

Elongation

(mm)

1346-410

12/6

12/7

100/200

100/200

160/320

160/320

14/7

100/200

160/320

14/8

100/200

160/320

1G/8

100/200

160/320

16/9

100/200

160/320

18/9

100/200

160/320

18/10

100/200

160/320

20/10

100/200

150/300

20/11

100/200

150/300

22/11

100/200

150/300

22/12

100/200

150/300

Note: Prostheses with different diameters or sizes can be manufactured on customer demand.

Grafting

A dry, sterile DALLON® vascular prosthesis with the diameter close to that of the replaced arteries must be preclotted before applying heparin to the patient. Preclotting on the prosthesis wall ought to be performed with unheparinized blood.

 

The elongated prosthesis is filled with blood taken from the artery which is operated on after earlier clamping one (or two in bifurcated grafts) of its ends. Originally the wall of the prosthesis is heavily soaked, thus, the blood injection inside the graft must be repeated. The prosthesis is then left in a container until the blood has clotted. Next step is to massage the prosthesis thoroughly rubbing the blood in and removing air bubbles from the areas between the fibres and loops. The entire graft must be soaked in blood.

Following cutting of the artery and its preparation for an anastomosis blood clots must be squeezed and sucked away from the inside of the prosthesis, its proximal end must be cut in appropriately to perform the anastomosis. The vascular suture can be applied in a way to maintain equal spaces between the punctures and sutures away from the edge of the prosthesis. This safeguards the tightness of the sutures. Next step is to wash and suck out the remaining clots by a single blood stream through the unfinished peripheral anastomosis (by relieving the clamp on the artery). Doing so we finish the suture of the peripheral anastomosis and we restore the blood flow.

Originally the prosthesis may show moderate porosity. In that case, it is necessary to repeatedly press the proximal fragment of the prosthesis with your fingers for a dozen seconds in order to seal it. Putting a thick layer of gauze pads on the prosthesis with moderate pressing on it aids the sealing process.

 

Note

  • Prostheses stained with blood in advance must not be used in a repeated surgery.

  • Excess handling the prosthesis with metal instruments needs to be avoided; when necessary clamp the graft only with soft vascular clamps with rubber covers.

  • Avoid clamping the prosthesis at its bifurcation.

  • When the prosthesis is sealed it should not be touched with any instruments.

 

Minimum „surgical” porosity and bigger „biological” porosity promote the artery replacement without excess blood loss and facilitate good and quick healing in of the prosthesis and its long term patency.

 

Sterilization

DALLON® double velour prostheses are offered as sterile products. A colored marker on the packaging inside the box indicates sterilization performed on the material. The product cannot be resterilized.

Storage

DALLON®  hydrophilic vascular prostheses should be stored in airy dark rooms in conditions preventing wetting and damaging either mechanical or chemical.

 

 

 

Click on the picture above to see the video presentation of DALLON® graft (Real Media)

 

 

Surgery using DALLON® graft (Real Media)

 

References

1.         M.H. Struszczyk, P. Bednarek,  K. Raczynski, „Synthetic vascular prostheses”, Polim. Med.,  2002, 32:1-2:13-22

2.         Krzysztof Ziaja, Marek Błaszczyński, Irena Wolny, Grzegorz Kies, Tomasz Urbanek, Tomasz Ludyga, „Proces wgajania się dallonowej protezy naczyniowej w układzie tętniczym człowieka. Analiza morfologiczna materiału pozyskanego w trakcie badania sekcyjnego”, Chirurgia Polska, 2001, 4 (3), 179-188

3.          J. Skóra i in., „Wczesna odpowiedź komórkowa i humoralna po wszczepieniu protezy naczyniowej w układ tętniczy”, Polimery w medycynie, 1997, 27, 3-4

4.          W. Strygan i in., “Ocena zespolenia protezy naczyniowej z tętnicy przy zastosowaniu kolorowego Dopplera”, Polski Przegład Chirurgiczny, 1993, 65, 800-806

5.          J. Piecuch  i in., „Doświadczalna i morfologiczna przydatność polskiej protezy dwustronnie welurowanej użytej do połączeń tętniczo-żylnych dla celów hemodializy”, Polski Przegląd Chirurgiczny, 1992, 64, 409-416

6.          S. Głowiński i in., „Wpływ tworzyw różnych typów protez naczyniowych na płytki krwi, układ krzepnięcia i fibrynolizę”, Polimery w Medycynie, 1992, 22, 4

7.          S. Głowiński i in., „Zmiana aktywności składników układu krzepnięcia  i fibrynolizy w warstwach przeszczepów Dallon dwustronny welur w różnym czasie po wszczepieniu do aorty”, Polimery w Medycynie, 1992, 22, 4

8.          L. Zimoch i in., „Porównanie procesów wgajania się protez naczyniowych Dallon standard i Dallon dwustronny welur”, Polimery w Medycynie, 1992, 22, 4

9.          S. Głowiński i in., „Porównanie aktywności ketapsyny D przeszczepów Dallon standard i Dallon dwustronny welur wszczepionych w aortę brzuszną”, Polimery w Medycynie, 1992, 22, 4

10.       S. Głowiński i in., „Zawartość i rozmieszczenie kolagenu w przeszczepach aortalnych Dallon dwustronny welur”, Polimery w Medycynie, 1992, 22, 4

11.       S. Głowiński i in., Porównanie aktywności składników układu hemostatycznego warstwy wewnetrznej przeszczepów Dallon  standard i dwustronny welur”, Polski Przegląd Chirurgiczny, 1990, 62, 11, 915-921

12.      L. Zimoch i in., „Badania morfolgiczne i ultrastrukturalne aortalnych przeszczepów Dallon dwustronny welur”, Polski Przegląd Chirurgiczny, 1990, 62, 11, 907-913

 

Information brochure