Knitted
Polypropylene-Polyester Prostheses
Used for
Cranioplasty
CHARACTERISTICS
CODUBIX® prostheses are ideal for reconstruction of skull
bone defects and they have the following properties:
·
good deformability
·
save from mechanical
damage when external forces are applied
·
extreme strength
·
low mass density
·
close to none water
absorption
·
good healing
·
radioparent features
·
easy physical
identification with natural cranial bones
Bearing no contraindications CODUBIX® prostheses are recommended for
plastic surgery of skull cap defects.
SIZE
|
Mark
|
Size (mm)
|
SWW 1346-490
|
|
Length
|
Width
|
Curvature height
|
KTM
|
|
R-0
|
**
|
**
|
**
|
010-690
|
|
R-1
|
130
|
125
|
24
|
010-191
|
|
R-2
|
134
|
110
|
19
|
010-293
|
|
R-3
|
105
|
60
|
10
|
010-395
|
|
R-4
|
75
|
75
|
12
|
010-497
|
|
R-5
|
75
|
75
|
12
|
010-599
|
** custom made prostheses
USE
Prior to sterilization it is necessary to precisely determine:
·
size of cranial
defect
·
shape of cranial
defect
·
curvature plane that
should fit natural construction of the skull.
Final adjustment of the prosthesis to the bone defect is performed
during a surgical operation. The prosthesis can be cut with a knife or
scissors. After modelling, the prosthesis should be thoroughly cleaned of
the dust that is created during fashioning by rinsing in physiological salt
solution.

STERILIZATION
CODUBIX® prostheses are supplied together with a fixing suture and
are non-sterile. Autoclave sterilization at the temperature of 121°C for 30
minutes is recommended. The prostheses can be sterilized twice, but not
more.
STORAGE
CODUBIX® prostheses should be protected against light and
stored in dark, airy rooms at the temperature of 20°C, with the relative
humidity of 65%. Wetting and mechanical or chemical damage should be
avoided.
|

Click on the picture above to see the video presentation
of
CODUBIX® by Real Media

Implantation of
CODUBIX® prosthesis (video by Real Media)
References:
1.
R. Rola, „Porównanie przebiegu okresu pooperacyjnego chorych po
plastyce kości sklepienia czaszki z użyciem autogennego płata kostnego i za
pomocą CODUBIX”, Medycyna Praktyczna. Neurotraumologia 1/1999, 77-80
2.
J. Kowalewska i in., „Zastosowanie protezy z dzianej przędzy
polipropylenowo-poliestrowej CODUBIX do wypełnienia rozległego ubytku w
ścianie klatki piersiowej”, Polski Przegląd Chirurgiczny 1997, 69, 8,
839-842
3.
W. Marć, „Leczenie
ubytków kości pokrywy czaszki z zastosowaniem materiału plastycznego
CODUBIX”, Neur. Neurochir. Pol.
Suplement, 1/1992,
4.
M. Buczek, „Jednoczasowe protezowanie opony twardej i kości po
otwartym złamaniu sklepienia czaszki”, Polski Przegląd Chirurgiczny 1992,
64, 7, 836-838
5.
P. Kowański, „Pourazowa przepuklina mózgowa kości pokrywy czaszki
usunięta operacyjnie”, Polski Przegląd Chirurgiczny 1992, 64, 9, 821-823
Information brochure

|